go-v.orgdoi

CellVizio ® System for Mesothorax Lymphadenopathy Rapid on Site, 18G needle: Pros and Cons

Paul Zarogoulidis, Wolfgang Hofenforst-Schwidt, Haidong Huang, Stavros Τryfon, Yifei Zhang, Guoren Ma, Kyriakos Amarantidis, Elena Maragouli, Vasilis Papadopoulos, Εleni-Isidora Perdikouri, Vagelis Voulgaris, Lutz Freitag, Chrysoula Margioula‐Siarkou, Theodora Tsiouda, Paschalis Ntolios, Stamatis Petousis, Konstantina Triantafyllopoulou, Kosmas Tsakiridis, Nikolaos A. Courcoutsakis, Sofia Baka · Journal of Cancer · 2026

  • DOI 10.7150/jca.136122
  • Publisher Ivyspring International Publisher
  • Type article
  • Issued 2026

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Journal of Cancer · Ivyspring International Publisher · article · 2026

Abstract

Introduction: The best tissue sample is still very important for the diagnosis of mesothorax lymphadenopathy. In the past 20 years endobronchial ultrasound (EBUS) has been used efficiently in most cases of primary lung cancer disease or metastatic disease. Several new type of needles have been created such 19G, 18G and hybrid biopsies with cryoprobes. Rapid on-site evaluation (ROSE) is used as an additional initial diagnostic tool. Confocal microscopy is a method of rapid on-site evaluation.

Patients and Methods: One hundred patients with mesothorax lymphadenopathy were biopsied with ebus and two groups were created one with rapid on-site evaluation with confocal microscopy and one by an operator with microscopic evaluation with sample preparation on cytoglasses. Our main objective was to assess parameters such as time, false negative results between the two techniques and technical issues such as the accessibility and evaluation between the two techniques. Safety was also evaluated. Results: catheter was less possible in a few cases due to rigid angles within the airways especially for small lymphnodes ≤ 1.5 cm (L4L mainly).

Discussion: Confocal is a safe and time-efficient technique for mesothorax lymphadenopathy. A high level of training is required for pulmonary physicians in order to assess the novel imaging technique. Definitely different parts of the lymphnode have to reached and evaluated in order to have a proper initial evaluation.

Open the resolved locator · 10.7150/jca.136122

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 21:09 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.jcancer.org/v17p1187.htm
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.