go-v.orgdoi

Thermal comfort and material performance in post-war heritage houses: A case study from M’lang, North Cotabato, Philippines

Sheena Marie Redil Franco · International Conference of the Architectural Science Association (ANZAScA) · 2025

  • DOI 10.65388/nmvt8326
  • Publisher OpenAlex
  • Type conference-paper
  • Issued 2025

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

International Conference of the Architectural Science Association (ANZAScA) · OpenAlex · conference-paper · 2025

Abstract

Philippine heritage architecture reflects cultural and environmental adaptation, with post-war houses in M'lang, North Cotabato embodying vernacular responses to tropical conditions.This study investigates how building form and materiality influence thermal comfort in such structures.Using plan-form analysis, Building Coverage Ratio (BCR), and material classification, the research examined spatial layouts, orientation, and envelope composition.Indoor thermal conditions were monitored over three consecutive days in September 2025 across multiple rooms and heights, complemented by outdoor data from NASA POWER.Comfort assessment employed the ASHRAE 55 adaptive model rather than fixed temperature bands.Results show that reinforced concrete ground floors with ceramic finishes moderated indoor temperatures, while timber upper levels exhibited heat accumulation, with midday peaks up to 38 °C.Relative humidity followed a diurnal cycle, highest in morning and evening (60-76%), lowest at noon (34-45%), mirroring outdoor patterns with reduced amplitude indoors.Adaptive analysis indicated that while midday peaks exceeded acceptable thresholds, morning and evening values occasionally aligned with comfort zones based on running-mean outdoor temperatures (26-27 °C).A short occupant survey (n = 1) confirmed discomfort during noon periods and reliance on open windows and shaded areas for relief.These findings demonstrate both the climatic ingenuity and limitations of traditional construction.Passive strategies such as orientation, large openings, and lattice partitions remain culturally relevant, yet insufficient under extreme heat.The study argues for minimally invasive retrofits-external shading, improved cross-ventilation, and reflective ceiling treatments-that respect historical authenticity while enhancing occupant comfort.

Open the resolved locator · 10.65388/nmvt8326

Metadata licence: OpenAlex metadata (CC0)