go-v.orgdoi

Dynamic Fixation Versus Trans-Syndesmotic Screw Fixation in Ankle Fractures With Syndesmotic Injury: Functional Outcomes, Complications, and Need for Reintervention

Andrés Ricardo Arévalo Sánchez · IECCMEXICO · 2026

  • DOI 10.64784/356
  • Publisher OpenAlex
  • Type article
  • Issued 2026

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

IECCMEXICO · OpenAlex · article · 2026

Abstract

Syndesmotic injury associated with ankle fractures represents a relevant challenge in orthopaedic trauma because inadequate stabilization may compromise ankle congruence, functional recovery, and long-term joint preservation. Trans-syndesmotic screw fixation has traditionally been used as the standard stabilization method; however, concerns related to implant rigidity, screw breakage, symptomatic hardware, and the need for secondary procedures have promoted increasing interest in dynamic suture-button fixation.

This study comparatively evaluated both fixation strategies through a systematic review of clinical evidence, focusing on functional outcomes, syndesmotic reduction, postoperative complications, implant-related events, and reintervention. Randomized controlled trials, comparative studies, systematic reviews, meta-analyses, and long-term follow-up investigations were analyzed according to predefined eligibility criteria. Functional recovery was primarily assessed using the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot Score and the Olerud-Molander Ankle Score.

Dynamic fixation showed consistently favorable functional results, although the magnitude of the differences did not always exceed clinically meaningful thresholds. The most pronounced differences were identified in implant-related complications and secondary surgical procedures. Suture-button fixation was associated with substantially lower rates of implant breakage and hardware removal and with a reduced risk of unplanned reoperation. Earlier evidence also suggested lower syndesmotic malreduction with dynamic fixation, although more recent pooled analyses have not consistently confirmed a statistically significant difference in this outcome.

Overall, dynamic fixation appears to provide functional outcomes that are at least equivalent to those achieved with trans-syndesmotic screws while offering a more favorable complication and reintervention profile. Nevertheless, both techniques remain effective when anatomical reduction is achieved, and fixation selection should consider fracture morphology, syndesmotic instability, patient characteristics, rehabilitation requirements, implant availability, and surgeon experience.

Open the resolved locator · 10.64784/356

Metadata licence: OpenAlex metadata (CC0)