go-v.orgdoi

Impact of Arteriovenous Fistula on Cardiac Size and Function in Kidney Transplant Recipients: A Retrospective Evaluation of 5-Year Echocardiographic Outcome

Marios Papasotiriou, Ioanna Xanthopoulou, Theodoros Ntrinias, Pantelitsa Kalliakmani, Nikolaos Koutsogiannis, Periklis A. Davlouros, Dimitrios S. Goumenos, Evangelos C. Papachristou · Experimental and Clinical Transplantation · 2019

  • DOI 10.6002/ect.2018.0331
  • Publisher Başkent University
  • Type article
  • Issued 2019

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Experimental and Clinical Transplantation · Başkent University · article · 2019

Abstract

OBJECTIVES: The effect of a functioning arteriovenous fistula on cardiac function in kidney transplant recipients has not been thoroughly investigated. MATERIALS AND METHODS: We retrospectively evaluated cardiac function in 99 renal transplant recipients using transthoracic echocardiography, with available follow-up at baseline and 2 and 5 years posttransplant. Patients were divided into 2 groups: a control group (n = 47) with no functioning arteriovenous fistula immediately after transplant and an arteriovenous fistula group (n = 52) with a functioning arteriovenous fistula for at least 5 years after transplant.

Left ventricular ejection fraction, diastolic thickness of the interventricular septum, and left ventricular end-diastolic diameter were assessed. RESULTS: In our study, patients (62.6% men, 7.1% with diabetes, mean age of 55.6 ± 11.5 years), we observed no significant differences with respect to baseline left ventricular ejection fraction and interventricular septum; however, in the arteriovenous fistula group, baseline left ventricular end-diastolic diameter was marginally higher than that shown in the control group (50.6 ± 5.4 vs 48.6 ± 4.4 mm; P = .054).

In multivariate analysis, functioning fistula and peripheral arterial disease were negatively associated with left ventricular ejection fraction at 5 years posttransplant, whereas baseline left ventricular ejection fraction had a minimal positive effect: B (95% confidence interval) of -2.186 (-4.312 to -0.061) (P = .044), -5.304 (-9.686 to -0.922) (P = .018), and 0.247 (0.047 to 0.446) (P = .016), respectively. Functioning fistula also emerged as associated with larger left ventricular end-diastolic diameter at 2 and 5 years posttransplant: B (95% confidence interval) of 3.047 (1.470-4.625) (P < .001) and 2.122 (0.406-3.838) (P = .016), respectively.

CONCLUSIONS: Maintenance of a functioning fistula in kidney transplant recipients may be associated with adverse long-term effects on left ventricular ejection fraction and left ventricular end-diastolic diameter.

Open the resolved locator · 10.6002/ect.2018.0331

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 13:21 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.ectrx.org/detail/archive/2019/17/5/0/619/0
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.