Data_production_Workflow_2026_05_20.ipynb
Dominique Daudon, Marine Blaise · Recherche Data Gouv France · 2026
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
Recherche Data Gouv France · OpenAlex · dataset · 2026
Abstract
Raw and processed data files for Maison en Terre,. Raws are in *.CSV format, and processed data are in *.nc format. Contains all 61 distincts measurments, with outliers removed. After processing, data is fully organized by themes, for better replication and understanding of every community.
You will find, in this dataset and ZIP files : All 61 measurements included, in a file called : Interior CO₂ (north and south), CO₂ (PPM) Micro-particles (µg/m3) Interior temperature (north and south), percieved temperature and temperature (°C) Interior humidity (north and south), absolute and relative humidity (%) Pyranometer measurements (W/m², kWh/m²) Azimuth and solar elevation Weather station temperature and sensor state (°C, boolean) Front, left, right and maximum light intensity (lux) Wind speed (m/s) Rain Convectors, light, outlets and ventilation energy consumption Convectors, light, outlets and ventilation power Volatile Organic Compounds (PPM) Roof, south walls (exterior, interior and middle), north walls (same as south walls) and walls temperature (°C) The same 61 measurements are regrouped in a file called Finally, measurements are organized following this list : Air quality: Interior CO₂ (north and south), CO₂ (PPM) and micro-particles (µg/m³) Climatic parameters: Interior temperature (north and south), perceived temperature and temperature (°C), interior humidity (north and south), absolute and relative humidity (%), pyranometer measurements (W/m², kWh/m²), azimuth and solar elevation, weather station temperature and sensor state (°C, boolean), front, left, right and maximum light intensity (lux), wind speed (m/s) and rain.
Energetic performance: Connectors, light, outlets and ventilation energy consumption. Connectors, light, outlets and ventilation power (W). Maison en terre structure: Roof, south walls (exterior, interior and middle), north walls (same as south walls) and walls temperature (°C) All data can be used to replicate the provided workflows. All these netCDF files can be used to compare with own data, and are targeted towards students, researchers, and environmental office workers.
Open the resolved locator · 10.57745/figeuv