Abstract

In 1995, Kavoussi et al. (Kavoussi et al., 1995) reported their findings on their experience with the accuracy and use of a robotic surgical arm compared with a human assistant during LUS. They found that the positioning of the camera was significantly steadier with fewer unwanted or abberant movements when under robotic control when compared with the human counterpart. There was no significant difference, however, in the total operative times using the robot or human assistant.

In a later study, by the same team looked at the use of surgeon-controlled robotic arms as a substitute for human assistants and found that simultaneous use of remote-controlled robotic arms as surgical assistants was feasible in minimally invasive surgery (Partin et al., 1995). They found that when the robotic arms were deployed, there was little increase in the total operating time. Furthermore, there was no difference in set up and breakdown times. The quest for replacements to human assistants was not just confined to urologists alone. Several non urological surgeons explored the potential of alternative camera drivers.

One team (Benin et al., 1995), explored the motions of the human camera operator and expressed them mathematically by use of a spherical displacement model. This led to the development of a revolving robotic arm with six degrees of freedom in close association with a camera. This was tested in animal models for cholecystectomy and other procedures. Another team (Geis et al., 1996) explored robotic arm enhancement and its effect on efficiency and resource optimisation in complex minimally invasive surgical procedures. They found that robotic arm enhancement reduced costs and minimized risk for patients.

In their study of the actual general surgical cases, they found that versatility, safety and reduction in burden of resources had an overall beneficial advantage. With health economics in mind, Turner (Turner et al., 1996) compared the cost-effectiveness of using a robotic versus a human assistant in a series of laparoscopic bladder neck suspension cases. His conclusion was that the overall cost of deploying and using the robotic arm was less than that of using a human assistant and that the former was a costeffective mode for performing the procedures.

In an analysis of several studies to determine whether the robotic arm can effectively provide the surgeon with complete control of the surgical field, and the impact of this device on overall cost, it was found that a robotic arm not only outperformed human camera assistants but also improved efficiency and cost savings (Dunlap & Wanzer 1998). The current price of the EndoAssist? and AESOP? devices are under $100,000 US. From a health economics point of view, these costs when balanced against use of man power and cost per hour of employing a human camera assistant, points in favour of the non-human-controlled camera devices.

The preliminary findings that robotic camera holders were economically and technically feasible led several groups to compare the actual devices in terms of different parameters of

Open the resolved locator · 10.5772/5259

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 22:01 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.intechopen.com/chapters/657
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.