Non-contact Quantitative Microwave Detection of Radiation Induced Degradation of Polymers (III)
武義 砂川, 昭紀 佐伯, 修平 関, Takeyoshi Sunagawa, Akinori Saeki, shu Seki · 福井工業大学研究紀要 · 2012
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
福井工業大学研究紀要 · OpenAlex · article · 2012
Abstract
In 2012, there are 50 commercial nuclear power plants in Japan. There are 20 nuclear power plants which are working for 30 years or more. It is very important to measure the aged deterioration of the cable used in those nuclear power plants. Generally, degradation of a cable was measured by the tensile test. It was difficult to measure an electrical property quickly and nondestructively. We developed the nondestructive measurement technology of cable degradation which used microwave technology.
Open the resolved locator · 10.57375/00000072