Observation of heat flux and evaporation at Awara in 2012
康行 宇治橋, Ujihashi, Yasuyuki · Institutional Repositories DataBase (IRDB) · 2013
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
Institutional Repositories DataBase (IRDB) · National Institute of Informatics · article · 2013
Abstract
The heat fluxes and evaporation rate are observed by three methods at Awara observation site near Lake Kitagata, Awara City Fukui Prefecture in 2012. One is the water balance method using soil columns and two are meteorological methods, Bowen ratio method and eddy correlation method with heat budget equation. The measured latent heat flux by using Bowen ratio is 8.2% smaller than that of by eddy correlation method. The difference of evaporation rate between measured by soil columns and meteorological methods are ranging -0.3 to 0.28 mm/h.The differences are mainly cause to poor accurate of the soil column method.
Open the resolved locator · 10.57375/00000033
Metadata licence: OpenAlex metadata (CC0)