go-v.orgdoi

Incidence And Radiography Of Upper Cervical Spine Injury In Blunt Head Injury In A Rural Hospital Setting

— · The Internet Journal of Radiology · 2008

  • DOI 10.5580/f1
  • Publisher OpenAlex
  • Type article
  • Issued 2008

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

The Internet Journal of Radiology · OpenAlex · article · 2008

Abstract

Objective: The purpose of this study is to look at the incidence and determine whether standard plain cervical spine radiographs are adequate in detecting C1 and C2 fractures in patients with blunt head injury. Materials and Methods: We prospectively studied 112 patients admitted to our hospital with blunt head trauma from whatever cause. All patients with blunt head trauma reffered for CT scan of the cranium had a routine CT scan of C1 and C2 Vertebra. The plain x-ray of cervical spine, CT scan of C1 and C2 vertebra were read by consultant radiologist who was not involved in the patient management.

The author then compared the relative abilities of plain films and compared with CT scans as referenced standard to detect fractures of C1 and C2 vertebrae. Results: A total of 2 (1.7%) fractures of C1 and a total of 9 (8.0%) fractures of C2 were demonstrated, with a total of 11(9.8%) fractures. For C1 fracture, plain radiograph has a sensitivity of 100.0%, specificity of 98.2%, positive predictive value of 50.0%, negative predictive value of 100.0% and correctly classified of 98.2%. For C2 fracture, plain radiograph has a sensitivity of 33.3%, specificity of 98.1%, positive predictive value of 60.0%, negative predictive value of 90.5% and correctly classified of 93.1%.

For C1 and C2 fracture in combination, plain radiograph has a sensitivity of 45.4%, specificity of 98.2%, positive predictive value of 55.5%, negative predictive value of 97.3% and correctly classified of 95.6%. Conclusion: The overall results of the study suggest that plain cervical spine radiographs are still reliable if used as the sole screening modality in the detection of C1 and C2 fractures in rural setting where availability of CT is scarce.

Open the resolved locator · 10.5580/f1

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 01:28 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://doi.org/10.5580/f1
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.