go-v.orgdoi

Contralateral Nostril acts as Conduit for Nasotracheal Tube Exchange under Fiberbronchoscope Guidance

— · The Internet Journal of Anesthesiology · 2008

  • DOI 10.5580/671
  • Publisher Internet Scientific Publications
  • Type article
  • Issued 2008

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

The Internet Journal of Anesthesiology · Internet Scientific Publications · article · 2008

Abstract

Purpose: Fiberoptic bronchoscopy aids in direct visualization of the airway and can provide visual guidance for exchange of nasotracheal tubes intraoperatively in head and neck surgeries where the full access for direct laryngoscopy and other airway manipulations will interfere and infect the exposed surgical field. Clinical Features: A 54-year-old male patient was planned for central arch resection with plate and myocutaneous flap reconstruction. After induction of anesthesia, fiberbronchoscope size 4. 9 mm was passed through the left nostril and after confirmed visualization of carina, reinforced cuffed tracheal tube size 7.5 mm inner diameter was threaded over it.

At the beginning of reconstructive phase of surgery, air leak was heard with suspected tracheal tube cuff damage. For tube exchange under direct visualization, the bronchoscope, loaded with new reinforced cuffed tracheal tube size 7.5 mm, was passed through the right nostril. The bronchoscope was passed between the anterior commissure and the outer surface of the damaged tracheal tube. As the cuff was already damaged and lying collapsed, the fiberbronchoscope easily slid along the outer surface of the damaged tracheal tube and reached carina.

After confirmation of the visualization of carina, the damaged tracheal tube was withdrawn through the left nostril leaving the bronchoscope endotracheal in situ; and immediately afterwards the new tracheal tube was passed to reintubate trachea within ten seconds. Conclusions: This technique is effective and smooth as this two-minutes-technique underwent under direct visualization with little difficulty and less than ten seconds interruption in mechanical ventilation during the actual tube exchange.

IMPLICATIONS STATEMENT Endotracheal tube exchange is a risky procedure and fiberoptic bronchoscopy guidance per contralateral nostril is better alternative to airway exchange catheter for nasotracheal tube exchange.

Open the resolved locator · 10.5580/671

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 00:59 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
http://doi.org/10.5580/671
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.