A case of severe metal hypersensitivity post tibial plating
— · The Internet Journal of Orthopedic Surgery · 2009
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
The Internet Journal of Orthopedic Surgery · OpenAlex · article · 2009
Abstract
Metal hypersensitivity is a well-recognised phenomenon post implantation of orthopaedic devices, though rarely tested for or considered prior to implantation ofsaid devices. Our report outlines a case of severe metal hypersensitivity to stainless steel, and raises the issue of a need for preoperative screening of patients for metal sensitivity prior to implantation. Studies would suggest a baseline incidence of nickel sensitivity in the general population to be in the order of 10-15%12, with the rates doubling in those with chronic nickel exposure.
The role such hypersensitivity plays in hardware failure, pain, and cutaneous reactions remains unproven in clinical studies, though many cases, such as this one, suggest a direct causal relationship.