Complications of Volar Locking Plates for Distal Radius Fractures: Experience of a District General Hospital
— · The Internet Journal of Orthopedic Surgery · 2008
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
The Internet Journal of Orthopedic Surgery · OpenAlex · article · 2008
Abstract
Background: The role of volar locking plates in the treatment of distal radial fractures is unsettled. The objective of this study is to evaluate the complications of this treatment method in a district general hospital setting. Methods: We retrospectively reviewed the radiological and clinical records of 52 consecutive patients who were treated using volar locking plates between November 2004 and August 2006. Results: Forty-eight patients were available for review at an average follow-up of 14 months (6-26 months).
Fifteen patients had one or more complications; median nerve compression symptoms (nine patients), hard-ware related complications (four patients), superficial wound infection and stitch abscess (three patients), malunion (two patients), failure of fixation and loss of reduction (two patients) and complex regional pain syndrome (two patients). A total of seven re-operations were performed. Discussion & Conclusions: Due to the high complication rate in this study, we recommend a more reserved attitude toward the use of distal radial volar locking plates.
Open the resolved locator · 10.5580/1024
Metadata licence: OpenAlex metadata (CC0)