DOI · e01.org

Comparison of ultrasonography and magnetic resonance cholangiopancreatography in the evaluation of obstructive jaundice: A cross-sectional observational diagnostic accuracy study.

Sanjai Sunil MBBS, G. V. Parvatheswara Rao MBBS, Veeranki Indira · Student s Journal of Health Research Africa · 2026

  • DOI 10.51168/saag8837
  • Publisher OpenAlex
  • Type article
  • Issued 2026

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Student s Journal of Health Research Africa · OpenAlex · article · 2026

Abstract

Background Obstructive jaundice requires accurate identification of the level, extent, and cause of biliary obstruction to guide treatment. Ultrasonography (USG) is widely used as an initial investigation, whereas magnetic resonance cholangiopancreatography (MRCP) provides non-invasive multiplanar evaluation of the biliary and pancreatic ducts. Objectives To compare USG with MRCP in patients with obstructive jaundice, evaluate the cause, level, and extent of obstruction, identify anatomical variants, and assess diagnostic performance against intra-operative findings.

Methods This cross-sectional observational diagnostic accuracy study included 50 patients with clinically and biochemically suspected obstructive jaundice referred to the Department of Radiology, Siddhartha Medical College, Vijayawada, from December 2022 to May 2024. Participants underwent USG and MRCP. Intra-operative findings served as the reference standard. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were assessed. Results The mean age was 49.14 ± 16.51 years, and 56.0% were women. Pain abdomen was the commonest presenting complaint (36.0%). The mean serum bilirubin was 3.80 ± 1.72 mg/dL.

Intra-operative findings showed benign lesions in 76.0% and malignant lesions in 24.0%; common bile duct calculus was the most frequent diagnosis (28.0%). USG demonstrated sensitivity of 71.23%, specificity of 95.0%, positive predictive value of 93.86%, negative predictive value of 86.0%, and diagnostic accuracy of 83.0%. Corresponding MRCP values were 92.0%, 97.0%, 92.3%, 97.2%, and 96.0%. Conclusion MRCP showed superior overall diagnostic performance, particularly sensitivity, negative predictive value, and accuracy, while USG retained high specificity and practical value as an initial assessment.

Recommendations USG should remain the first-line screening examination, followed by MRCP when detailed characterization, distal duct assessment, anatomical mapping, or clarification of inconclusive findings is required.

Open the resolved locator · 10.51168/saag8837

Metadata licence: OpenAlex metadata (CC0)