Abstract

In effect-directed analysis (EDA), the coupling of a chromatographic separation process is understood using a biological test system. The benefit with this approach is that the previously separated substances contained in the sample are detected in vitro in a test system, on the basis of your activity. It has been demonstrated that high performance liquid chromatography (HPLC) is particularly eligible for the EDA. The research literature indicated that the EDA is performed with the HPLC on different samples but was not used as a routine method, e.g. for identifying contaminated sites.

In this work, detecting the endpoint of the bioluminescence inhibition (Aliivibrio fischeri), antibiotic effect (Bacillus subtilis), and neurotoxicity (Acetylcholinesterase) of the HPLC plate was optimized with regard to routine capabilities. It could additionally be demonstrated in the first trials that it is possible to prove direct genotoxic links using the umu test on the HPLC plate. Different incubation times are required for the individual biotests. This leads to a brand broadening due to diffusion on the HPLC plate. Different methods and ways of working to minimise diffusion were tested and optimized.

Mechanical containment is one possibility, where gauze is inserted into the solidified calcium alginate layer. The process was optimized on the Bacillus subtilis inhibition assay. A comparatively short incubation period is necessary for enzyme tests. As a result a shorter band broadening occurs, whereby the mechanical containment of the diffusion is not eligible. In order to keep the occurring band broadening as minimal as possible, application of the substrate in particular was optimized. This occurred, as an example, with the HPLC acetylcholinesterase inhibition assay.

In comparison to the process described in the literature, outcomes could be substantially improved by spraying the substrate. The statistical method of "design of experiment" is used for determining different band broadening determinants. Using this knowledge, the method could be optimized to such an extent that the band broadening occurring when detecting AChE inhibitor can be kept very minimal. Based on the high sensitivity of the procedure, low traces of impurities can be detected in the reference substances. The comparability of the outcomes is particularly necessary for routine use of the EDA with the HPLC.

Furthermore, an evaluation strategy was compiled using the HPLC luminescent bacteria inhibition assay with Aliivibrio fischeri. Determining the bioluminescence inhibition takes place analogous to the cuvette test and can be represented as a chromatogram inhibition value that is resolved on location. The representation of inhibition in a inhibition-value chromatogram partially offsets the compression of the peaks based on the sigmoid process of the dose-response relationship. It is necessary to set a reference point for comparing samples due to using the non-linear relationship between concentration or surface dimension and the effect of the unknown substances. EC50 value was proven for this.

However, since the concentration is unknown in most cases, the application volume selected as the reference point is chosen based on what is required to trigger an inhibition of 50%. The inverse of the calculated application volume for 50% inhibition represents the reciprocal iso-inhibition volume (RIHV). This RIHV value was proven for the sample comparison in different applications. The principle for the evaluation can, with adjustment, be transferred from the HPLC luminescent bacteria test to the HPLC Bacillus subtilis inhibition assay. In accordance with the RIHV, the reciprocal iso-activity volume (RIAV) is used for comparing the effect on the acetylcholinesterase inhibition.

Here the application volume is added as an inverse, which is necessary to reach an acetylcholinesterase activity of 50%. Reference compounds were assessed parallel to the samples for determining the measurement uncertainty of the chromatography and the detected effect. When monitoring a protected landfill over a period of 4.5 years, it could be demonstrated that it concerns a reproducible chromatographic system with HPLC/AMD.

Standard deviations of 5-9% inhibition for the test-specific reference substances were determined when applying the luminescent bacteria, Bacillus subtilis- and the acetylcholinesterase inhibition assay on different landfill and waste water samples over a period of 7 months. As an outcome of the validation, the HPLC Aliivibrio fischeri-, HPLC Bacillus subtilis and the HPLC acetylcholinesterase inhibition assay was accredited on 24/03/2015 by the Deutschen Akkreditierungsstelle (DAkkS [German Accreditation Body]). The umu test was selected for determining potential genotoxic substances.

Using the umu test on the HPLC plate, it is possible to detect the effective genotoxic substance 4-nitroquinoline-N-oxide (4-NQO) known from DIN 38415-3 on the HPLC plate. It is not possible to keep the required metabolising system upright on the HPLC plate to successfully detect the indirectly acting substances, which only have a genotoxic effect after activation by the metabolic enzymes. An enrichment is necessary to perform the EDA for most water samples (e.g. surface water or ground water). The enrichment of organic compounds from water samples is optimized in parallel to the work with biological test systems.

Different materials were tested for the solid-phase extraction (SPE) with substances of various polarities for pH values 2, 7 and 9. The best recovery across the entire polarity range was achieved by the phase "Agilent Plexa" (polydivinylbenzene) with an adjusted elution sequence. When selecting the material and adjusting the elution sequence, a blank value as low as possible was regarded on the bioluminescence inhibition assay with Aliivibrio fischeri. Consequently, an enrichment method eligible for the EDA was found.

To improve the extraction yield of polar compounds using liquid-liquid extraction (LLE), the micro LLE were tested along with the extractant acetonitrile, which is miscible in water in all conditions. The occurring substances disturbing the blank value could be significantly reduced by heating the sodium chloride required for phase separation. Only few deviations in the inhibition value could be detected when investigating reproducibility with a landfill soil water sample and detecting the bioluminescence of Aliivibrio fischeri.

Based on the expected complex structure of samples from the landfill area, a gradient elution is necessary for the high performance liquid chromatography using automatic multiple development (HPLC/AMD). Based on the reference compounds and extracts from various landfills, the HPLC/AMD separation was optimised for a screening. With this screening gradient, it is possible to distribute the acting sample constituents across the entire isolating distance. Moreover, a development of an isocratic HPLC separation still occurred for a quick assessment of the samples, whereby it was necessary for compromises to be made for this method with regard to separation efficiency.

Additionally, it could be demonstrated that the extensive identification process can be facilitated by specific post chromatographic derivatization reactions on the HPLC plate. The Bratton-Marshall test was optimised by primary amines. The conceivable structure can be significantly limited by testing the exchangeable protons using the H/D exchange. The coupling of HPLC and mass spectrometer was demonstrated as particularly eligible for a nearly complete H/D exchange because only a few millilitres on the deuterated solvent are required here. The optimized methods were tested on different water samples, which come from sewage treatment plants and from the surrounding landfill areas.

It is possible to comparatively assess water from different sampling locations, e.g. landfill leachate, by introducing RIHV or RIAV values based on their effect. This means that the change in impact pattern can be observed across treatment processes. The assessment outcomes also demonstrate that field blank tests are also crucial with the EDA in order to be able to reliably assess samples.