go-v.orgdoi

To Determine the Microbial Recovery from Different Surfaces Using a Standard Contact Plate Sampling Method

Tim Eaton, Karen Capper, C Tobin, J Bright · European journal of parenteral & pharmaceutical sciences · 2025

  • DOI 10.37521/ejpps29402
  • Publisher OpenAlex
  • Type article
  • Issued 2025

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

European journal of parenteral & pharmaceutical sciences · OpenAlex · article · 2025

Abstract

The most appropriate sampling method to be utilised by 55 mm diameter tryptone soya agar (with neutralisers) contact plates to recover naturally occurring surface microbial contamination from hard surfaces has previously been determined. This sampling method was used to investigate the recovery from different surfaces, typical of those that are routinely sampled in a cleanroom. These were a polyester garment, stainless steel, cleanroom latex gloves, workstation barrier EDPM gauntlets and cleanroom goggles copolyester lens.

The surfaces had been contaminated with microbe-carrying particles (MCPs) dispersed from people following exposure within heavily populated environments, and is more representative of the contamination that is found within cleanrooms. It was determined that the polyester garment, latex gloves and EPDM barrier gauntlet all had a recovery efficiency of around 70% and the copolyester lens goggles and stainless steel tray had a higher recovery of efficiency of around 80%.

Open the resolved locator · 10.37521/ejpps29402