Replication Data for: InSb/InP Core-Shell Colloidal Quantum Dots for Sensitive and Fast Short-Wave Infrared Photodetectors

Peng, Luncheng, Wang, Yongjie, Ren, Yurong, Wang, Zhuoran, Gerasimos Konstantatos · CORA.Repositori de Dades de Recerca · 2024

  • DOI 10.34810/data1799
  • Publisher Consorci de Serveis Universitaris de Catalunya
  • Type dataset
  • Issued 2024

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

CORA.Repositori de Dades de Recerca · Consorci de Serveis Universitaris de Catalunya · dataset · 2024

Abstract

UV−vis absorption measurements were performed with a Cary 5000 UV−vis−NIR spectrometer in solution. For photoluminescence (PL) measure-ments, a four-channel Thorlabs laser was used as the excitation light and a Kymera 328i spectrograph (Oxford Instruments, Andor) was used as the detector (<1600 nm). For PLQY measurement, a 935 nm laser, an integration sphere, and an Andor detector were used. The XRD data were collected using a Rigaku SmartLab powder diffractometer in the Bragg−Brentano geometry with Cu Kα radiation on drop-casted powder samples. The TEM images were obtained using a JEOL 2100F microscope operating at an accelerating voltage of 200 kV.

TEM samples were prepared by dropping a diluted QD solution on ultrathin carbon grids. Scanning transmission electron microscopy (STEM) experiments were conducted using an FEI Titan G2 80-200 microscope at 200 kV equipped with a Cs-probe corrector and a HAADF detector. Elemental maps were taken by energy-dispersive X-ray spectroscopy (EDX) using four large-solid-angle symmetrical Si drift detectors. The XPS/UPS measurements were performed with a SPECS PHOIBOS 150 hemispherical analyzer under ultrahigh-vacuum conditions (10−10 mbar) with a monochromatic Kα X-ray source (1,486.74 eV).

Current−voltage (I−V) measurements were performed with a Keysight Semiconductor Parameter Analyzer (B1500A) with the devices kept in a shield box. The EQE was measured using a Newport Cornerstone 260 monochromator, a Thorlabs MC2000 chopper, a Stanford Research SR570 transimpedance amplifier, and a Stanford Research SR830 lock-in amplifier. Calibrated Newport 818-UV and 818-IR photo- detectors were used as the reference. The nanosecond laser (520 nm) was used as incident light, which was modulated by a waveform generator (Agilent 33220A) at various frequencies with a 50% duty cycle to measure the 3dB bandwidth.

For linear dynamic range measurements, a four-channel laser (Thorlabs) at 1310 nm was used as a light source at a frequency of 7 Hz modulated by an Agilent waveform generator. For the noise measurements, devices were connected with a Stanford Research SR830 lock-in amplifier directly.

Open the resolved locator · 10.34810/data1799

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 01:18 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://dataverse.csuc.cat/dataset.xhtml
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.