Pine nut mono- and sesquiterpenoid fingerprints (Extracted Ion Chromatograms) obtained by HS-SPME-GC-MS
Berta Torres-Cobos, Nicotra, Soriana B., Asensio-Manzano, Celia, N. Aletà, Anna Teixidó, M. Rovira, Agustí Romero, Francesc Guardiola, Stefania Vichi, Alba Tres · CORA.Repositori de Dades de Recerca · 2024
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
CORA.Repositori de Dades de Recerca · Consorci de Serveis Universitaris de Catalunya · dataset · 2024
Abstract
A set of 253 pine nut samples from different geographical regions was obtained from 2020 to 2023 in the frame of the Tracenuts project (PID2020-117701RB-I00). Pine nut samples were analysed under HS-SPME conditions adapted from Vichi et al. (Journal of Chromatography A, 2006, 1125: 117-123. doi.org/10.1016/j.chroma.2006.05.029) using a Combi-pal autosampler (CTC Analytics, Zwingen, Switzerland). An aliquot of approximately 1 g of whole pine nuts was weighed into a 10 mL vial fitted with a PTFE/silicone septum.
The sample was conditioned at 70 °C for 10 min, followed by exposing a divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber (2 cm length, 50/30 μm film thickness) from Supelco (Bellefonte, Pennsylvania, USA) to the sample headspace for 60 min, at the same temperature. Then, the fiber was desorbed at 260 ˚C for 10 min in the gas chromatograph injection port, the injector was maintained in split-less mode for the first 5 min. The mono- and sesquiterpene fingerprint was acquired by an Agilent 6890N Network GC system coupled to a quadrupolar mass selective analyser Agilent 5975C Inert MSD (Agilent Technologies, Santa Clara, California, USA).
Helium was the carrier gas, at a flow of 1.5 mL/min. Analytes were separated on a Supelcowax-10 capillary column (60 m × 0.25 mm i.d., 0.25 μm film thickness) (Supelco, Bellefonte, Pennsylvania, USA). Column temperature was held at 40 °C for 3 min, increased to 100 °C at 4 °C/min, then, to 200 °C at 5 °C/min and to 260 °C at 15 °C/min, holding the last temperature for 5 min. The temperatures of the ion source and the transfer line were 230 and 280°C, respectively. Mass spectra were recorded at 2.3 scan/s and the electron energy was 70 eV.
Data acquisition was performed in the selected ion monitoring (SIM) mode, by registering the Extracted Ion Chromatogram (EIC) of 7 ions which have been reported to be characteristic of the mono and sesquiterpene compounds: m/z 93, 95, 119, 159, 161, 189 and 204.
Open the resolved locator · 10.34810/data1730
Metadata licence: OpenAlex metadata (CC0)