Abstract
Improvements in regenerators as well as the use of insulation have been a means of reducing energy consumption in glass manufacture. An increase in air preheating, moreover, has been an essential requirement for the essentially higher combustion space temperatures involved in increased melting efficiency. To be able to compute the effects of further improvements in regenerators knowledge of the heat transfer coefficient is an essential requirement. Heat and flow measurements have therefore been made on specially prepared regenerators attached to an operating glass tank to allow evaluation of the heat transfer in cruciform packing, for which up to now no data have existed in the literature.
Comparisons between data also measured for basket weave packing led to the conclusion that, for similar geometric data and flow conditions both types of packing behave very similarly so far as convective heat transfer is concerned. Flow measurements give homogeneous waste gas and air distributions in all the installations tested. Heterogeneities have a comparatively small influence on the energy consumption of glass tank furnaces.