Monitoring the Sleep Respiratory Rate with Low-Cost Microcontroller Wi-Fi in a Controlled Environment

Ratthamontree Burimas, Teerayut Horanont, Aakash Thapa, Badri Raj Lamichhane · Applied Sciences · 2024

  • DOI 10.3390/app14156458
  • Publisher Multidisciplinary Digital Publishing Institute
  • Type article
  • Issued 2024

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Applied Sciences · Multidisciplinary Digital Publishing Institute · article · 2024

Abstract

Sleep apnea, characterized by breathing interruptions or slow breathing at night, can cause various health issues. Detecting respiratory rate (RR) using Wireless Fidelity (Wi-Fi) can identify sleep disorders without physical contact avoiding sleep disruption. However, traditional methods using Network Interface Cards (NICs) like the Intel Wi-Fi Link 5300 NIC are often costly and limited in channel state information (CSI) resolution. Our study introduces an effective strategy using the affordable ESP32 single-board computer for tracking RR through detailed analysis of Wi-Fi signal CSI.

We developed a technique correlating Wi-Fi signal fluctuations with RR, employing signal processing methods—Hampel Filtering, Gaussian Filtering, Linear Interpolation, and Butterworth Low Pass Filtering—to accurately extract relevant signals. Additionally, noise from external movements is mitigated using a Z-Score for anomaly detection approach. We also implemented a local peak function to count peaks within an interval, scaling it to bpm for RR identification. RR measurements were conducted at different rates—Normal (12–16 bpm), Fast (>16 bpm), and Slow (<12 bpm)—to assess the effectiveness in both normal and sleep apnea conditions.

Tested on data from 8 participants with distinct body types and genders, our approach demonstrated accuracy by comparing modeled sleep RR against actual RR measurements from the Vernier Respiration Monitor Belt. Optimal parameter settings yielded an overall average mean absolute deviation (MAD) of 2.60 bpm, providing the best result for normal breathing (MAD = 1.38). Different optimal settings were required for fast (MAD = 1.81) and slow breathing (MAD = 2.98). The results indicate that our method effectively detects RR using a low-cost approach under different parameter settings.

Open the resolved locator · 10.3390/app14156458

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 01:42 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://doi.org/10.3390/app14156458
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.