Optical microscopy as a simple method for analysis of boiler tube failure
Milan T. Jovanovic, Zoran Mišković, Vesna M. MAKSIMOVIĆ, Ivana Cvijović‐Alagić · Metallurgical and Materials Engineering · 2020
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
Metallurgical and Materials Engineering · Association of Metallurgical Engineers of Serbia · article · 2020
Abstract
A severely damaged low carbon steel boiler tube was the object of this investigation. Detailed microstructural characterization was performed by optical microscopy, whereas scanning electron microscopy (SEM) was applied only in a few cases. Results show that a variety of microstructures was formed in the material of the damaged boiler tube during its exploitation. The failure of the tube is the result of very inhomogeneous overheating. The side of the boiler tube toward fire (F) was exposed to high overheating temperature, which in some locations was well above the A3 transformation temperature.
The side toward boiler (BL) was subjected to lower temperatures, i.e. in the region mostly between A1 and A3 temperatures. Variations in temperatures and cooling rates, which resulted in microstructural inhomogeneity, are the main cause for the formation and multiplication of stresses leading to the rupture of the tube.
Open the resolved locator · 10.30544/461
Metadata licence: OpenAlex metadata (CC0)