Contributions to develop enantioselective chromatographic processes

Ivana Mutavdžin · Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt) · 2017

  • DOI 10.25673/5259
  • Publisher Universitäts Frauenklinik
  • Type dissertation
  • Issued 2017

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Digitalen Hochschulbibliothek Sachsen-Anhalt (Universitäts- und Landesbibliothek Sachsen-Anhalt) · Universitäts Frauenklinik · dissertation · 2017

Abstract

Separation of enantiomers of medically relevant substances represents an important and challenging task. Still a larger number of drugs are produced and used as racemic mixtures, containing both enantiomers in equal amounts. One such example are fluorinated volatile anaesthetics isoflurane and desflurane, which are investigated in this work. Although many preliminary studies reported different pharmacological and toxicological effects of two enantiomers of these substances, they are still applied in the racemic form during surgeries. To investigate their effect further, larger amounts of single enantiomers are required.

The main task of this thesis was to develop a procedure for the production of pure enantiomers of isoflurane and desflurane using gas chromatographic separation. For this a suitable cyclodextrin-based selector, developed in preliminary works, could be exploited. While the processes in the liquid phase have been widely investigated and known, preparative gas chromatography is still not present at great extent in the research and application. Another chiral system (bicalutamide enantioseparation using liquid chromatography) was additionally examined by experiments and simulations.

This system served to better understand separation phenomena and as a reference system to provide validation of some of the procedures developed. To properly analyse adsorption processes and for their design and optimization, it is essential to know the adsorption isotherms. One of the goals of this study was to provide understanding of the process thermodynamics by quantifying the adsorption isotherms. It starts with testing two dynamic methods that can be applied for isotherm determination in chiral systems.

One is the known peak-fitting method, which was analysed for the application on the investigated systems, while the other method is newly developed extension of the elution by characteristic point that was here derived for a binary mixture. Subsequently, the gas-chromatographic process was simulated using thermodynamic data for the applied cyclodextrin stationary phase. The simulation study was conducted in order to identify the operating parameters which would provide the highest possible production of the pure enantiomers. The performance of larger columns was investigated by simple scale-up relations.

Finally, also a capture step was described for isolating the pure components and storing them after the separation in non-selective columns. Some of the predictions were experimentally confirmed in an accompanying project. In addition, the enantioseparation using a continuous multi-column pressure swing adsorption process was theoretically studied and compared in terms of productivity to the batch gas chromatography. Experimental data acquired in a parallel project, show that the here developed simple theoretical concept together with the determined adsorption isotherms can be successfully applied to describe gas chromatography processes for diluted systems.

It was demonstrated that it is feasible to produce enough amounts of pure enantiomers of anaesthetic gases, which are essential for performing further medical tests.

Open the resolved locator · 10.25673/5259

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 01:51 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
http://nbn-resolving.de/urn:nbn:de:gbv:ma9:1-11078
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.