Removal of technetium-99 from simulated Oak Ridge National Laboratory Newly-Generated Liquid Low-Level Waste
TN (United States) Oak Ridge K-25 Site, D Beck, USDOE, Washington, DC (United States), P.E. Osborne, D.H. Bunch, R Fellows, G Sellers, J.L. Shoemaker, K Bowser, D Bostick · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1995
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1995
Abstract
We report laboratory investigations on treatment options for the removal of the radionuclide {sup 99}{Tc} (as the pertechnetate anion, {Tc}O{sub 4}{sup {minus}}) from simulated Oak Ridge National Laboratory Newly Generated Liquid Low-Level Waste. The waste stimulant is alkaline (pH 12-13), containing sodium carbonate ({approximately}0.10 mot/L) and sodium hydroxide ({approximately} 0.125 mol/L), plus a modest concentration of sodium nitrate ({approximately}0.06 mol/L). Several organic resin anion exchange media were tested; Dowex{trademark} 1-X-8 and Reillex{trademark} HPQ resins were notably effective (with equilibrium distribution coefficients {approximately}2,000 mL/g, as-received basis).
We also tested steel wool as a reagent to chemically reduce and sorb {sup 99}Tc. At pH values above {approximately}10, the iron surface was passivated and became ineffective as a reagent for technetium; however, as the test solution pH value was adjusted to near-neutrality (e.g., pH 8-9), the steel was noted to be more effective than the organic resins tested.
In dynamic flow conditions, steel wool packed in a column was noted to continuously leak {approximately}1--3% of the amount of {sup 99}{Tc} activity in the feed solution, although no additional increase in eluent activity was noted for the duration of the testing ({approximately}1200 bed volumes of {approximately}0.11 mg/L {sup 99}{Tc} flowed at a rate equivalent to {approximately}0.5 gal/min/ft{sup 2} of column cross sectional area).
Although no breakthrough was noted (other than the 1--3 % continuous ``bleed`` noted previously) during the column operation ({approximately} 2 weeks), the steel in the column was deteriorated, causing plugging and erratic flow toward the end of the testing interval.