Review of window and filter requirements for commissioning of the Advanced Photon Source insertion device beamlines
IL (United States) Argonne National Lab., Tuncer M. Kuzay, USDOE, Washington, DC (United States) (US), Zhibi Wang · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1994
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1994
Abstract
The Advanced Photon Source (APS) is building 16 insertion device (ID) front ends for the first phase of the project. Eleven of these are to be equipped with the APS Undulator A and the other five with a Wiggler-A-type source. The Undulator A front ends are designed to operate in a ``windowless`` mode using an APS-designed differential pump. However, during beamline commissioning and early operations of the storage ring, it is prudent to install windows to ensure storage ring vacuum safety before easing into windowless operation. However, the window designed for this interim period may not meet all the needs of a user`s scientific program.
In the early phases of the project through commissioning and start of operations, such a window will permit the user to prepare for his program, while allowing both the user and the facility operators to gain experience for safe phasing into eventual windowless operations. In this report, we will present analysis and design options for a variety of windows particularly suited to either the APS Undulator A front ends or as user windows located in the first optics enclosure (FOE).
Open the resolved locator · 10.2172/91925
Metadata licence: OpenAlex metadata (CC0)