The detection of slug failure by monitoring the activity of the discharge water
Not Available · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1951
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1951
Abstract
The effluent water monitoring system essentially consists of a cyclic monitoring of the beta activity of the water from each discharge header and riser. The normal activity of the water is measured by an ion chamber and registered on a Beckman meter. A program has been instituted under the guidance of the 100 Areas Program Committee to reduce the maintenance and design troubles so that positive indication of fission products can be immediately seen. This should avoid unnecessary scrams and consequent loss of power from false indications and improve the sensitivity of the system.
This document presents operational problems that have arisen in the detection of slug failure, a bibliography of pertinent documents with excerpts of pertinent data, proposed immediate minor improvements, and a scoping of further necessary investigations to insure positive and quick determination of ruptured slugs. This information represents the results of collective study of P Division, Inst. Division, and Technical Personnel. 5 tabs.
Open the resolved locator · 10.2172/6991821
Metadata licence: OpenAlex metadata (CC0)