Abstract

Direct coal-fired turbine concepts currently being developed require substantial levels of sulfur removal from high-temperature gas streams. Calcium-based sorbents, limestones, dolomites, limes and lime hydrates, are capable of sulfur removal in direct coal-fired turbine combustor environments at temperature up to 1200/degree/C. Two types of desulfurizer processes are considered in this report using calcium- based sorbents: fluidized bed desulfurizer using coarse sorbent particles (300-1000 ..mu..m), and entrained desulfurizer using fine sorbent particles (1-40 ..mu..m).

Small-scale laboratory tests were performed on a variety of calcium-based sorbents to determine the kinetics of sulfation and sulfidation over ranges of conditions applicable to both types of desulfurizer processes. Correlations are developed in the report for the effect of pressure; temperature, and particle size. Engineering models are also developed for both desulfurizer types that incorporate the laboratory reaction kinetics and predict potential commercial performance and performance trends.

It is concluded that both desulfurizer concepts can be effective in direct coal-fired turbines, with calcium-to-sulfur molar feed ratios ranging from 1.5 to 3.0, if the correct calcium-based sorbent is selected, and if applicable design and operating conditions are identified. Both desulfurizer concepts have limitations and key development requirements, and site and fuel specific engineering assessment is required to select the best concept for a given combustor system. The influence of the desulfurizer concepts on turbine protection, through their influence on particle loading and alkali release must also be assessed. 51 refs., 73 figs., 9 tabs.

Open the resolved locator · 10.2172/6963243

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 21:23 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.osti.gov/servlets/purl/6963243
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.