Block V solar cell module: design and test specification for intermediate-load applications, 1981
Jet Propulsion Lab., Pasadena, CA (USA) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1981
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1981
Abstract
The requirements for the design and test of terrestrial solar cell modules for one phase of DOE's Low-Cost Solar Array Project are presented. Intermediate-load modules designed to meet this specification will generally have the following design features and characteristics: (1) nominal operating voltage (V/sub no/) between 5 Vdc and 20 Vdc; (2) ability to be series-connected to worst-case open-circuit voltages of 1000 Vdc; (3) dimensions not exceeding 1.22 m x 2.44 m (4 ft x 8 ft); (4) flat-plate configuration (non-concentrating); and (5) output power referenced to nominal operating conditions and V/sub no/.
In addition to module design and performance requirements, a series of characterization and qualification tests are also specified.