Effects of upper-plenum steam condensation phenomena on heat transfer in a rod bundle. [PWR]
W.Y. Chon, C. Addabbo, N.S. Liao · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1980
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1980
Abstract
System performance and thermohydraulic response to simultaneous bottom and top water injection were investigated in a 3 x 3 rod bundle Reflood Test Facility. An extensive series of tests, encompassing both simple bottom and combined injection reflooding, were carried out. A number of phenomenological events governing the thermodynamic coupling between the bottom reflood updraft and the top deluge were identified. Due to the countercurrent motion of the upflowing steam and water injected in the upper plenum counter current flow limiting phenomena hindered the penetration of water from inventory in the upper plenum into the bundle section.
Consequently, condensation phenomena in the upper plenum and in the venting pipework characterized the thermohydraulic response of the bundle to simultaneous bottom and top water injection.
Open the resolved locator · 10.2172/5437263
Metadata licence: OpenAlex metadata (CC0)