LOCAL BOILING PRESSURE DROP
J.B. Reynolds · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1954
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1954
Abstract
Local boiling pressure drop data for forced circulation of distilled water in a uniformly heated, horizontal, Type 347 stainless steel tube (3/8 in.ID x 1/2 in.OD x 6 ft long) is c orrelated within ± 20% over thefoUowing range of variables* heat fluxes from 130,000 to 304,000 Btu/(hr) (sq ft); mass velocities from 343 to 652 lb/(sec) (sq ft) (corresponding to inlet water velocities of 7 to 10.6 fps)j and pressures from 45 to 100 psia.Graphical comparison of local boiling pressure drop to isothermal pressure drop shows a maximum ratio of approximately 2.6 "
Open the resolved locator · 10.2172/4367243
Metadata licence: OpenAlex metadata (CC0)