go-v.orgdoi

ENERGY DEPENDENCE OF ALBEDO NEUTRON DOSIMETERS PLACED ON THE HEAD.

N. Mex Los Alamos Scientific Lab, Dale E. Hankins · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1970

  • DOI 10.2172/4123003
  • Publisher Office of Scientific and Technical Information
  • Type report
  • Issued 1970

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1970

Abstract

A study was made of the energy dependence of an albedo neutron dosimeter system placed at various loca tions on the head.An albedo dosimeter placed behind the ear has an energy dependence closer to the desired rem response than a chest-mounted dosimeter.The im provement in the energy response is greatest for inter mediate-and low-energy neutrons, but the response for fast-energy neutrons is still poor.The large overresponse of an albedo dosimeter caused by room-scattered neutrons and shielding mate rials placed between the source and the dosimeter is described.The directional effect of a head-mounted albedo dosimeter was better than a chest-mounted do simeter.

Open the resolved locator · 10.2172/4123003

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 21:34 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.osti.gov/biblio/4123003
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.