Abstract
A study was made of the energy dependence of an albedo neutron dosimeter system placed at various loca tions on the head.An albedo dosimeter placed behind the ear has an energy dependence closer to the desired rem response than a chest-mounted dosimeter.The im provement in the energy response is greatest for inter mediate-and low-energy neutrons, but the response for fast-energy neutrons is still poor.The large overresponse of an albedo dosimeter caused by room-scattered neutrons and shielding mate rials placed between the source and the dosimeter is described.The directional effect of a head-mounted albedo dosimeter was better than a chest-mounted do simeter.