go-v.orgdoi

An examination of criticality accident alarm coverage of the X-710, X-760 Buildings and the north half of the X-7745-R storage pad at the Portsmouth Gaseous Diffusion Plant

USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP), C Skapik, Portsmouth Gaseous Diffusion Plant, OH (United States), M Dobelbower, J Woollard, B Lee, Jr · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1996

  • DOI 10.2172/201802
  • Publisher Office of Scientific and Technical Information
  • Type report
  • Issued 1996

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1996

Abstract

This report summarizes the results of an evaluation of Criticality Accident Alarm System (CAAS) coverage of the X-710 and X-760 buildings and the north half of the X-7745-R storage lot located east of the X-7725 building at the Portsmouth Gaseous Diffusion Plant. In order to evaluate coverage, the facilities were modeled using the Monte Carlo N-Particle Transport Computer Code (MCNP). MCNP was then used to simulate criticality accidents at various locations in the X-710 and X-760 buildings and the north half of the X-7745-R storage lot. The associated neutron flux at current detector locations was calculated.

The neutron flux was then converted to an absorbed dose rate (in tissue) and compared with the Portsmouth criticality accident alarm set-point of 5mrad/hr. The parameters defining the simulated criticality accidents have been calculated as ``the minimum accident of concern`` as defined in ANSI Standard ANS 8.3-1986. These calculations are documented in Portsmouth report POEF-SH-31. The results of this evaluation indicate that the X-710 and X-760 buildings and surrounding roads are adequately covered by the CAAS systems that are currently in place in those buildings. The X-7745-R storage pad is also adequately covered by the CAAS in the X-7725 building.

Open the resolved locator · 10.2172/201802

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-20 03:42 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.osti.gov/biblio/201802
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.