AC compensation of 3D magnetic diagnostic signals in DIII-D and NSTX-U for real-time application.
S. Munaretto, Clayton E. Myers, Stefan P Gerhardt, N.C. Logan, Jonathan E. Menard, E. J. Strait · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 2022
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · conference-paper · 2022
Abstract
produced by the plasma challenging. Although the DC coupling between coils and sensors can be easily calculated and removed, the AC part is more difficult. Here, an algorithm based on a layered low-pass filter approach for the AC compensation and its application for DIII-D and NSTX-U data is presented, showing that this method reduces the vacuum pickup to the noise level. Comparison of plasma response measurements with and without vacuum compensation shows that accurate mode locking detection and plasma response identification require precise AC and DC compensations.
Open the resolved locator · 10.2172/2003221