go-v.orgdoi

RML Dosimetry Conversions for SNL Reference Benchmark Neutron Fields

Sandia National Laboratories (SNL), Albuquerque, NM (United States). New Mexico Small Business Assistance (NMSBA) Program, NM (United States), Patrick Griffin, USDOE Assistant Secretary for Human Resources and Administration, Parma, Richard Vega, David W. Vehar · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 2019

  • DOI 10.2172/1761853
  • Publisher Office of Scientific and Technical Information
  • Type report
  • Issued 2019

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 2019

Abstract

Neutron dosimetry monitors should be used during all irradiations in the Annular Core Research Reactor. This report provides the recommended conversion factors that should be used to translate the monitor dosimeter read-outs into the damage metrics that are typically used by experimenters to assess the results of their experiment. These conversion factors are based upon the use of the latest least-squares adjusted neutron spectrum determination to describe the Sandia National Laboratories reference neutron fields and the latest International Atomic Energy Agency recommended dosimetry cross sections to capture the response of the dosimeter.

The resulting conversion factors are built into the dosimetry results routinely provided by the Radiation Metrology Laboratory.

Open the resolved locator · 10.2172/1761853

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 21:24 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://www.osti.gov/biblio/1761853
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.