The National Ignition Facility (NIF) is capable of providing enough energy to explore areas of physics that are not possible on any other laser system. This includes large-volume, geometrically complex hydrodynamic and radiation hydrodynamic experiments in which traditional, line integrated radiographic techniques limit the quality of the results. As an example, we are involved in divergent hydrodynamic experiments at the NIF, motivated by supernova hydrodynamics, that cannot be diagnosed in detail with transmission radiography. We initially considered imaging x-ray scattering for this purpose and it appears feasible.
However, a better candidate is fluorescence imaging as the cross section of photoabsorption in the several-keV range is roughly 100 times larger than that of scattering. A single layer of the target will be uniformly doped with a fluorescent tracer, which will be pumped by a sheet of x-rays. The fluorescent intensity will be measured to create a density map of the doped material as it mixes with other layers. Developing this diagnostic will create a powerful tool to characterize hydrodynamic experiments with complex geometries.