Engineering review of stainless steel clad thermocouple elements
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation, V FitzPatrick, USDOE, Washington, DC (United States) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1963
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Office of Scientific and Technical Information · report · 1963
Abstract
To evaluate the crudding characteristics of ammonium hydroxide conditioned coolant it is necessary to use a thermocouple element. The present design has accentuated structural integrity, reliability and constant heat flux. A radical departure from past designs was made by selecting a stainless steel cladding and enriched ceramic fuel. Three thermocouples are inserted in the cladding to increase the reliability. By the use of two thermocouple elements it will be possible to obtain important preliminary information on preferential crud deposition while simultaneously evaluating the crudding characteristics of ammonium hydroxide conditioned coolant.
Open the resolved locator · 10.2172/10145461
Metadata licence: OpenAlex metadata (CC0)