go-v.orgdoi

THE DETERMINATION OF DOPAC OVER POLYANILINEPOLY( 3-METHYLTHIOPHENE)-POLY(3,3’- DIAMINOBENZIDINE) ELECTRODE

Muammer Kavanoz, Emine Ülker · Journal of the Turkish Chemical Society Section A Chemistry · 2015

  • DOI 10.18596/jotcsa.80098
  • Publisher Turkish Chemical Society
  • Type article
  • Issued 2015

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

Journal of the Turkish Chemical Society Section A Chemistry · Turkish Chemical Society · article · 2015

Abstract

3,4-dihydroxyphenylacetic acid (DOPAC) which is important metabolite of dopamine is an important biological molecules [1]. DOPAC with dopamine play an important role in the treatment of neurological disorders such as schizophrenia [2], epilepsy [3], Parkinson's disease [4] Alzheimer [5]. Because of the physiological importance, accurate and reliable determination of DOPAC is important clinically. The redox property of DOPAC allows its electrochemical detection.

Various modified electrodeswith conductive polymer were used for the determination of DOPAC in the literature [6].In this study, Polyaniline - Poly(3-methylthiophene) - Poly(3,3’-diaminobenzidine) (PANI - P3MT - PDAB) film which has PANI and P3MT (good conductive polymers) and PDAB (multiple amine functional groups) was potentiodynamically synthesized on Pt disk electrode in methylene chloride layer by layer.

For this, green colored PANI film was deposited on Pt disk electrode in methylene chloride containing 100 mM tetrabuthyl ammonium perchlorate (TBAP) / 300 mM aniline / 100 mM HClO4 thenblack colored P3MT – PDAB film was deposited on PANI film in methylene chloride containing 100 mM TBAP / 500 mM 3-methylthiophene / 1.0 mM 3,3’-diaminobenzidine. Characterization of PANI-P3MT–PDAB film was performed by UVvis, FT–IR, SEM and EDS methods. This film was used amperometric determination of DOPAC in solution consists of NaHSO4/Na2SO4 (pH 2.0). It was studied at 0.45 V, 0.50 V, 0.55 V and 0.60 V potentials for amperometric determination of DOPAC with this modified electrode.

The best analytical data were obtained 0.50 V. Limit ofDetection (LOD), Limit of Quantification (LOQ), the linear response range and regression coefficient (R2) were found as 1.47x10-5 mM, 4.49x10-5 mM, 4.49x10-5 – 2.0 mM and 0.981, respectively.

Open the resolved locator · 10.18596/jotcsa.80098

Metadata licence: OpenAlex metadata (CC0)

Registry
OpenAlex DOI index + API
Fetched
2026-11-19 21:24 UTC
Cache state
not cached yet (bulk-index+openalex)
Locator
https://dergipark.org.tr/en/pub/jotcsa/article/201873
Metadata licence
OpenAlex metadata (CC0)
Scope
Metadata as returned by the resolver; abstracts are never generated here.