Direct Detection of Manganese Ions in Organic Electrolyte by UV-vis Spectroscopy
Lihong Zhao, Étienne Chénard, Ömer Özgür Çapraz, Nancy R. Sottos, Scott R. White · Journal of The Electrochemical Society · 2018
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
Journal of The Electrochemical Society · Institute of Physics · article · 2018
Abstract
Lithium manganese oxide cathodes used in Li-ion batteries suffer from manganese dissolution and capacity fade. We present a new technique for directly measuring the manganese ion (Mn 2+ ) concentration in a typical Li-ion carbonate electrolyte using 4-(2-pyridylazo) resorcinol (PAR) as a UV-vis probe. Chelation between PAR and Mn 2+ ion induces a characteristic absorption peak where the peak intensity corresponds to Mn 2+ ion concentration in the electrolyte. Electrochemical stability of the probe is verified by performing potential hold and cyclic voltammetry. The in situ characterization of Mn dissolution in a customized battery cell is performed during cyclic voltammetry.
Open the resolved locator · 10.1149/2.1111802jes
Metadata licence: OpenAlex metadata (CC0)