Gap Test Calibrations And Their Scalin

Harold W. Sandusky · AIP conference proceedings · 2012

  • DOI 10.1063/1.3686355
  • Publisher American Institute of Physics
  • Type conference-paper
  • Issued 2012

Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.

AIP conference proceedings · American Institute of Physics · conference-paper · 2012

Abstract

Common tests for measuring the threshold for shock initiation are the NOL large scale gap test (LSGT) with a 50.8-mm diameter donor/gap and the expanded large scale gap test (ELSGT) with a 95.3-mm diameter donor/gap. Despite the same specifications for the explosive donor and polymethyl methacrylate (PMMA) gap in both tests, calibration of shock pressure in the gap versus distance from the donor scales by a factor of 1.75, not the 1.875 difference in their sizes. Recently reported model calculations suggest that the scaling discrepancy results from the viscoelastic properties of PMMA in combination with different methods for obtaining shock pressure.

This is supported by the consistent scaling of these donors when calibrated in water-filled aquariums. Calibrations and their scaling are compared for other donors with PMMA gaps and for various donors in water.