Measurement of x-ray absorption coefficients of some common metals for the 1.5–3-keV range
L. Singman · Journal of Applied Physics · 1974
Not cached yet. This record was fetched live for this request and is stored after the lookup. Reopening the page should serve the cached copy.
Journal of Applied Physics · American Institute of Physics · article · 1974
Abstract
The x-ray absorption coefficients of the metals Al, Ti, Fe, Ni, Cu, and Zn have been measured for radiations in the 1.5–3-keV range. Monochromatic x rays were obtained by diffracting characteristic x-ray lines with a crystal. Freedom from fluorescent radiation was ensured by using crystals of low-Z material. The absorber thicknesses as well as the time distributions between measuring I and I0 were optimized. The average of nine transmission measurements taken with the absorber in nine different positions was used in computing the absorption coefficients for each element.
Comparison of absorption coefficients obtained with different absorbers of the same element indicates an experimental uncertainty of 1–4%.
Open the resolved locator · 10.1063/1.1663509
Metadata licence: OpenAlex metadata (CC0)